RESPIRATORY
PROTECTION
Respiratory
Protection
 |
OSHA requires the use of
specific levels of respiratory protection when handling hazardous
contaminants. |
|
SCBA – Self Contained Breathing Apparatus:
 |
SCBA
is the greatest form of respiratory protection used in
Level A & B emergency response.
It is a positive air-supplying respirator that allows a
designated time of air to flow through a full-face gas mask. |
|
Scott
SCBA:
 |
Protects workers from Immediately Dangerous to Life &
Health (IDLH) atmospheres; Ammonia IDLH is 300 ppm. |
 |
Provides 30 minutes of air when pressurized at 2216 psi,
low pressure |
 |
Features an air-saver switch with automatic restart |
 |
Mounts on back frame for better balance and less fatigue |
 |
Includes bell alarm |
 |
Contains a hairnet with 4-point suspension to prevent
pulling |
SCBA
with composite cylinder
SCBA with aluminum cylinder
Part #: 5050
Part #: 5051
|
PAPR – Positive Air-Purifying
Respirator:
 |
PAPR
provides positive flowing filtered air through a
respirator. It is
generally used when workers’ lungs are not strong enough to
utilize a negative pressure cartridge gas mask as determined by a
Medical Evaluation or where worker's are required to where a
respirator for long shifts.
|
|
|

|
Breathe-Easy 7 PAPR System:
 |
Lightweight, non-restrictive respirator |
 |
Provides a steady flow of air for up to eight hours |
 |
Includes the following components: |
Headpiece
Breathing Tube
Single Cartridge Turbo Unit
Cartridge
Battery Charger
Part #: 5090
|
Full Face Cartridge
Respirator:
 |
Respirators
allow workers to breathe easily in atmospheres below
Immediately Dangerous to Life and Health (IDLH) levels.
It is a negative pressure mask that allows the contaminated
air to be filtered through a cartridge specific to the contaminant
type.
|
|
|

|
Scott-O-Vista
Full Face Cartridge Respirator:
 |
Wide-view lens for broad field of vision |
 |
Mesh hair net prevents pulling |
 |
Hard coat treated lens resists abrasion and
chemicals |
 |
Neoprene rubber seal conforms to facial contours |
 |
Two cartridges included with respirator |
Part #: 5091
|
For
questions, comments or additional information, please contact us at:
R.
M. Technologies Inc.
Phone: 800-775-4280
Fax: 888-533-4884
E-Mail:
generalmail@rmtech.net
|
 |